Home batteries · the register

Is it on the register?

3,430 home battery storage devices that have been through a type test, from the Energy Networks Association’s Connect Direct register. Search it by manufacturer, by the model number on the label, or by system reference — and every device has its own page and its own URL, which the ENA’s own search does not.

3,430 of 3,430 storage devices

The manufacturer list shows the 120 with the most entries. Anything beyond that is reachable through the search box.

ManufacturerModelSystem referenceRegistered capacityPhasesG98 (GB)Published
Powervault Plus LTDPowervault 3POWEV/01527/V1/A13.68 kW11631 Oct 2020
Powervault Plus LTDPowervault 3POWEV/02621/V15.5 kW1031 Oct 2020
Social EnergyDURA3EBV1SOCEN/02576/V13 kW11521 Oct 2020
TeslaPowerwallTESLA/00216/V1/A43.68 kW11615 Oct 2020
Victron Energy B.V.Multiplus II 48/5000/70-50VICEN/02551/V14.4 kW1013 Oct 2020
Victron Energy B.V.Multiplus II 48/3000/35-32 GXVICEN/02557/V12.47 kW1013 Oct 2020
Victron Energy B.V.Multiplus II 48/5000/70-50 GXVICEN/02560/V14.4 kW1013 Oct 2020
Moixa EnergyMSB V3C 2kWh & 3kWh Moixa Smart BatteryMOIXA/01144/V1/A10.43 kW1012 Oct 2020
SMASTPS-60SMAST/00334/V1/A260 kW308 Oct 2020
Sofarsolar Co. LtdHybrid Inverter/HYD 3000-ESSOFAR/02477/V13 kW11630 Sept 2020
Sofarsolar Co. LtdHybrid Inverter/HYD 3600-ESSOFAR/02478/V13.68 kW11630 Sept 2020
Sofarsolar Co. LtdHybrid Inverter/HYD 4000-ESSOFAR/02479/V14 kW1030 Sept 2020
Sofarsolar Co. LtdHybrid Inverter/HYD 5000-ESSOFAR/02480/V15 kW1030 Sept 2020
Sofarsolar Co. LtdHybrid Inverter/HYD 6000-ESSOFAR/02481/V16 kW1030 Sept 2020
Sofarsolar Co. LtdHybrid Inverter/ME 3000SPSOFAR/00651/V1/A23 kW1028 Sept 2020
LUXPOWER TECHNOLOGY CO.,LTDLXP-4K hybrid,LXP-4.6K hybrid, LXP-5K hybridLUXPO/01565/V1/A25 kW1024 Sept 2020
SINYMASI-70KR1SINYX/02192/V1/A170 kW3028 Aug 2020
Maitian Energy Co., Ltd.AC1-Prime-3.7-EMAITI/02197/V13.68 kW1163 Jul 2020
Maitian Energy Co., Ltd.AC1-Prime-3.0-EMAITI/02198/V13 kW1163 Jul 2020
StorTera (trade name for Power migration partners)DSR-R GridVerter 3.6STORT/02042/V1/A13.6 kW11621 Apr 2020
Alpha ESSSMILE T10ALPHA/01178/V1/A310 kW31620 Feb 2020
Alpha ESSSMILE B3ALPHA/01183/V1/A23 kW11620 Feb 2020
Alpha ESST30ALPHA/01542/V1/A230 kW3020 Feb 2020
SMASMA SBS 2.5-1VL-10SMAST/01832/V12.5 kW1012 Jan 2020
Sofarsolar Co. LtdHybrid Inverter/HYD 6000-ESSOFAR/00646/V16 kW1021 Jun 2019
Sofarsolar Co. LtdHybrid Inverter/HYD 5000-ESSOFAR/00647/V15 kW1021 Jun 2019
Sofarsolar Co. LtdHybrid Inverter/HYD 4000-ESSOFAR/00648/V14 kW1021 Jun 2019
Sofarsolar Co. LtdHybrid Inverter/HYD 3600-ESSOFAR/00649/V13.6 kW1021 Jun 2019
Sofarsolar Co. LtdHybrid Inverter/HYD 3000-ESSOFAR/00650/V13 kW1021 Jun 2019
TeslaPowerwallTESLA/00217/V1/A15 kW1021 Jun 2019

On a narrow screen the table scrolls sideways inside its own box — the page itself never does.

What being on this register means. The storage device has been type tested against G98 (and where it applies, G99) — the same engineering rules that govern anything generating or discharging alongside the grid, including the anti-islanding test.

What it does not mean. The register lists devices, not installations. It says nothing about who fitted yours, whether it was notified to your network operator, or whether the installer holds MCS certification.

Absence is not a finding. Manufacturers register under their legal name and an internal model code, and both routinely differ from the name on the retail box — “TSUNESS Co., Ltd” and “TSOL-ESK800-U” are not what a shop calls them. If you cannot find your equipment here, the most likely explanation is that it is listed under a name you have not tried.

What we do not publish. The register carries a status field. We do not repeat it, anywhere, for any device. We have asked the Energy Networks Association what its values actually mean and have not had an answer, and every plug-in solar device on the register — including all eleven currently marked as not compliant — shows a completed full G98 type test. Printing a word we cannot explain, against the name of a real manufacturer, thousands of times over, is not something we are prepared to do. Follow the link on any device page and read the ENA’s own entry.

Source: ENA Connect Direct type test register, Energy Networks Association. We mirror it daily and record what changes; we never edit it.