Home batteries · the register

Is it on the register?

3,430 home battery storage devices that have been through a type test, from the Energy Networks Association’s Connect Direct register. Search it by manufacturer, by the model number on the label, or by system reference — and every device has its own page and its own URL, which the ENA’s own search does not.

3,430 of 3,430 storage devices

The manufacturer list shows the 120 with the most entries. Anything beyond that is reachable through the search box.

ManufacturerModelSystem referenceRegistered capacityPhasesG98 (GB)Published
FOXESS Co., Ltd.PQ1-4.6-L-PFOXES/20707/V1/A24.6 kW13318 Aug 2026
Hangzhou Livoltek Power Co., Ltd.HES1-4K6S2HANGZ/20081/V1/A44.6 kW13318 Aug 2026
Hangzhou Livoltek Power Co., Ltd.HES1-5KS2HANGZ/20082/V1/A45 kW13318 Aug 2026
Hangzhou Livoltek Power Co., Ltd.HES1-5KS2CHANGZ/20083/V1/A45 kW13318 Aug 2026
Hangzhou Livoltek Power Co., Ltd.HES1-6KS2HANGZ/20085/V1/A56 kW13318 Aug 2026
Hangzhou Livoltek Power Co., Ltd.HES1-4K6S2-PHANGZ/20087/V1/A54.6 kW13318 Aug 2026
Hangzhou Livoltek Power Co., Ltd.HES1-5KS2-PHANGZ/20088/V1/A45 kW13318 Aug 2026
leapton energy co., ltd.H4000-LS2-G5LEAPT/20539/V1/A34 kW13318 Aug 2026
leapton energy co., ltd.H5000-LS2-G5LEAPT/20541/V1/A25 kW13318 Aug 2026
leapton energy co., ltd.H6000-LS2-G5LEAPT/20542/V1/A26 kW13318 Aug 2026
leapton energy co., ltd.H7500-LS2-G5LEAPT/20543/V1/A27.5 kW13318 Aug 2026
leapton energy co., ltd.H8000-LS2-G5LEAPT/20544/V1/A28 kW13318 Aug 2026
TeslaPowerwall 3TESLA/20594/V1/A411.04 kW13315 Aug 2026
TeslaPowerwall 3TESLA/20595/V1/A410 kW13315 Aug 2026
TeslaPowerwall 3TESLA/20596/V1/A49 kW13315 Aug 2026
TeslaPowerwall 3TESLA/20597/V1/A58 kW13315 Aug 2026
TeslaPowerwall 3TESLA/20598/V1/A57 kW13315 Aug 2026
TeslaPowerwall 3TESLA/20599/V1/A56 kW13315 Aug 2026
TeslaPowerwall 3TESLA/20601/V1/A55 kW13315 Aug 2026
TeslaPowerwall 3TESLA/20602/V1/A33.68 kW13315 Aug 2026
shenzhen hello tech energy co., ltdJS3-2500PA-GYSHENZN/20551/V1/A20.8 kW13314 Aug 2026
shenzhen hello tech energy co., ltdJS3-2500PA-GY-20SHENZN/20552/V1/A31.2 kW13314 Aug 2026
FOXESS Co., Ltd.PQ1-4.6-PFOXES/20699/V1/A24.6 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-5.0-PFOXES/20700/V1/A25 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-6.0-PFOXES/20701/V1/A26 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-7.0-PFOXES/20702/V1/A27 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-8.0-PFOXES/20703/V1/A28 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-10.0-PFOXES/20705/V1/A210 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-12.0-PFOXES/20706/V1/A212 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-5.0-L-PFOXES/20708/V1/A25 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-6.0-L-PFOXES/20709/V1/A26 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-7.5-L-PFOXES/20710/V1/A27.5 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-4.6-A-PFOXES/20712/V1/A24.6 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-5.0-A-PFOXES/20713/V1/A25 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-6.0-A-PFOXES/20714/V1/A26 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-7.0-A-PFOXES/20715/V1/A27 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-8.0-A-PFOXES/20716/V1/A28 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-10.0-A-PFOXES/20717/V1/A210 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-12.0-A-PFOXES/20718/V1/A212 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-4.6-L-A-PFOXES/20719/V1/A24.6 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-5.0-L-A-PFOXES/20720/V1/A25 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-6.0-L-A-PFOXES/20721/V1/A26 kW13313 Aug 2026
FOXESS Co., Ltd.PQ1-7.5-L-A-PFOXES/20722/V1/A27.5 kW13313 Aug 2026
Hangzhou Livoltek Power Co., Ltd.HES1-3KS2HANGZ/20078/V1/A33 kW13313 Aug 2026
Hangzhou Livoltek Power Co., Ltd.HES1-3KS2-PHANGZ/20079/V1/A33 kW13313 Aug 2026
Hangzhou Livoltek Power Co., Ltd.HES1-3K6S2HANGZ/20080/V1/A33.6 kW13313 Aug 2026
Hangzhou Livoltek Power Co., Ltd.HES1-5K5S2HANGZ/20084/V1/A35.5 kW13313 Aug 2026
Hangzhou Livoltek Power Co., Ltd.HES1-3K6S2-PHANGZ/20086/V1/A33.6 kW13313 Aug 2026
Hangzhou Livoltek Power Co., Ltd.HES1-5KS2C-PHANGZ/20089/V1/A45 kW13313 Aug 2026
Hangzhou Livoltek Power Co., Ltd.HES1- 5K5S2-PHANGZ/20092/V1/A35.5 kW13313 Aug 2026

On a narrow screen the table scrolls sideways inside its own box — the page itself never does.

What being on this register means. The storage device has been type tested against G98 (and where it applies, G99) — the same engineering rules that govern anything generating or discharging alongside the grid, including the anti-islanding test.

What it does not mean. The register lists devices, not installations. It says nothing about who fitted yours, whether it was notified to your network operator, or whether the installer holds MCS certification.

Absence is not a finding. Manufacturers register under their legal name and an internal model code, and both routinely differ from the name on the retail box — “TSUNESS Co., Ltd” and “TSOL-ESK800-U” are not what a shop calls them. If you cannot find your equipment here, the most likely explanation is that it is listed under a name you have not tried.

What we do not publish. The register carries a status field. We do not repeat it, anywhere, for any device. We have asked the Energy Networks Association what its values actually mean and have not had an answer, and every plug-in solar device on the register — including all eleven currently marked as not compliant — shows a completed full G98 type test. Printing a word we cannot explain, against the name of a real manufacturer, thousands of times over, is not something we are prepared to do. Follow the link on any device page and read the ENA’s own entry.

Source: ENA Connect Direct type test register, Energy Networks Association. We mirror it daily and record what changes; we never edit it.